Related Experiment Video
Updated: Dec 9, 2025

Study of In Vivo Glucose Metabolism in High-fat Diet-fed Mice Using Oral Glucose Tolerance Test OGTT and Insulin Tolerance Test ITT
Published on: January 7, 2018
Transoperative glycemia in pets: validating old ones, and presenting lip mucosa as new sampling site
P B Costa1, M L Ricarti2, C A A Augustavo2
1Campus Glória - Bloco 1CCG SALA 211A, BR-050, KM 78, Uberlândia, Minas Gerais 38410-337, Brazil; Graduate Program in Veterinary Science (PPGCVET), Universidade Federal de Uberlândia (UFU), Uberlândia, Minas Gerais, Brazil.
Abstract:
The aim of our study was to investigate the viability and validity of blood sampling from the upper lip mucosa in healthy dogs and cats for monitoring transoperative glycemia and compare the results with those obtained from samples taken from previously described blood sampling sites for determination of glycemia using a glucose meter. Blood glucose (BG) levels were determined in samples taken from the upper lip mucosa of 24 dogs and 31 cats undergoing neutering or spaying surgeries. These values were compared to those of samples obtained from other sites previously described for capillary blood glucose monitoring (marginal ear vein, carpal pad in dogs, metacarpal pad in cats) using a glucose meter. Additionally, BG from peripheral venous blood was determined using a glucose meter, and the gold standard enzymatic colorimetric assay. The clinical reliability of BG values taken from lip mucosa and from all the other BG values measured by the glucose meter was evaluated using the error grid analysis modified by Parkes et al (2000). The upper lip mucosa was an easily accessible site for the obtainment of appropriate blood samples, and glucose levels read in these samples correlated positively with glycemic values read in blood samples from all other sites in dogs and cats. All BG made using glucose meters taken from all sites were within the clinically acceptable range when compared with enzymatic colorimetric assay (gold standard), and were analytically accurate according to the error grid (zones A and B). All blood sampling sites described in this work can be used to assess transoperative glycemia. The upper lip mucosa is a viable blood sampling site for precise monitoring of transoperative glycemia in healthy dogs and cats and shows promise for alternative blood glucose monitoring.
More Related Videos
10:39Laser Doppler: A Tool for Measuring Pancreatic Islet Microvascular Vasomotion In Vivo
Published on: March 8, 2018
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes