A CNT-PDMS wearable device for simultaneous measurement of wrist pulse pressure and cardiac electrical activity
Li Wang1, Wenkun Dou2, Jun Chen1
1Advanced Micro and Nanoinstruments Center (AMNC), School of Mechanical & Automotive Engineering, Qilu University of Technology (Shandong Academy of Sciences), Jinan, Shandong 250353, China.
Abstract:
Simultaneous measurement of multi-physiological signals can provide effective diagnosis and therapeutic assessment of diseases. This paper reports a carbon nanotube (CNT) - Polydimethylsiloxane (PDMS) - based wearable device with piezo-resistive and voltage-sensing capabilities for simultaneously capturing wrist pulse pressure and cardiac electrical signal. The layout design of sensing elements in the device was guided by analyzing strain distribution and electric field distribution for minimizing the interference between wrist pulse and cardiac electric activity during measurement. Each device was preconditioned under the strain of 20% until the resistance change of the device reached equilibrium. After preconditioning, the relationship between the resistance change and the pressure was calibrated, which determined the device sensitivity to be 0.01 Pa-1 and the linear pressure range of the device to be 0.4 kPa to 14.0 kPa. Mechanisms of CNT-PDMS for sensing strain signal and electrical pulse signal were explored by scanning electron microscopy (SEM) imaging and equivalent circuit modeling. The device was applied to monitor the wrist pulse and ECG signals of volunteers during the recovering process after physical exercises.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Assessment Sites
Special considerations while measuring pulse