Survey of current perspectives on consumer-available digital health devices for detecting atrial fibrillation
Eric Y Ding1, Emma Svennberg2,3, Christina Wurster4
1Division of Cardiology, Department of Medicine, University of Massachusetts Medical School, Worcester, Massachusetts.
Background:
Many digital health technologies capable of atrial fibrillation (AF) detection are directly available to patients. However, adaptation into clinical practice by heart rhythm healthcare practitioners (HCPs) is unclear.
Objective:
To examine HCP perspectives on use of commercial technologies for AF detection and management.
Methods:
We created an electronic survey for HCPs assessing practice demographics and perspectives on digital devices for AF detection and management. The survey was distributed electronically to all members of 3 heart rhythm professional societies.
Results:
We received 1601 responses out of 73,563 e-mails sent, with 43.6% from cardiac electrophysiologists, 12.8% from fellows, and 11.6% from advanced practice practitioners. Most respondents (62.3%) reported having recommended patient use of a digital device for AF detection. Those who did not had concerns about their accuracy (29.6%), clinical utility of results (22.8%), and integration into electronic health records (19.8%). Results from a 30-second single-lead electrocardiogram were sufficient for 42.7% of HCPs to recommend oral anticoagulation for patients at high risk for stroke. Respondents wanted more data comparing the accuracy of digital devices to conventional devices for AF monitoring (64.9%). A quarter (27.3%) of HCPs had no reservations recommending digital devices for AF detection, and most (53.4%) wanted guidelines from their professional societies providing guidance on their optimal use.
Conclusion:
Many HCPs have already integrated digital devices into their clinical practice. However, HCPs reported facing challenges when using digital technologies for AF detection, and professional society recommendations on their use are needed.
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias VI: Management of Dysrhythmias
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...