Background:
"Exoview" is a three-dimensional (3D) image reconstruction software developed by our medical team independently. The aim of this retrospective study was to compare the use of 3D image reconstruction, and thin-section multi-detector computed tomography (MDCT) in the preoperative evaluation of the segmental artery (SA).
Methods:
From May 2018 to May 2019, 52 patients received anatomical segmentectomy in our department. All patients received computed tomography pulmonary angiography (CTPA) by use of a 64-slice MDCT before operation. Then the 2D CT data were converted into 3D format by use of Exoview. We compared the intraoperative findings of the SA branches with 3D images and thin-section MDCT.
Results:
The study cohort of 52 patients included 31 women and 21 men and the operative factors include operation time (148.75±53.56 min), blood loss (57.31±79.68 mL), postoperative hospitalization days (6.42±3.48 days), lymph node sampling (3.00±1.50 stations) and postoperative complications (5 patients, 10%). The adenocarcinoma in situ with microinvasion was the predominant type (25 cases, 48%). There were 7 patients accepted for video-assisted thoracoscopic surgery (VATS) lobectomy with radical lymph nodes dissection because invasive adenocarcinoma was confirmed by intraoperative frozen-section analysis. One other patient was confirmed for conversion from VATS segmentectomy to an open operation because of bleeding of the bronchial artery. According to intraoperative findings, 95.7% (132 of 138) and 100% (138 of 138) of these SA branches were precisely identified on preoperative 3D image reconstruction and thin-section MDCT images. The 6 missed branches were less than 1.4 mm in actual diameter.
Conclusions:
Both 3D image reconstruction and thin-section MDCT provided precise preoperative information about SA. The 3D image reconstruction software "Exoview" could visualize SA for surgeons. However, the thin-section MDCT provided a better evaluation of small SA branches.