Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Parallel RLC Circuits01:14

Parallel RLC Circuits

1.4K
Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
1.4K
Overcurrent Relays01:26

Overcurrent Relays

389
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
389
Lossy Lines and Overvoltages01:22

Lossy Lines and Overvoltages

280
Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
280
Reclosers and Fuses01:26

Reclosers and Fuses

365
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
365
Insulation Coordination01:23

Insulation Coordination

464
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
464
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

290
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
290

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Raising the Bar.

Journal of orthopaedic trauma·2025
Same author

Do Widespread or Selective Invasive Monitoring Increase the Rate of Fasciotomies for Tibial Shaft and Plateau Fractures, or Affect the Incidence of Possible Missed Compartment Syndrome?

The Journal of the American Academy of Orthopaedic Surgeons·2025
Same author

Commentary on: Study on Sustentaculum Tali Fragment Constancy in Intra-articular Calcaneus Fracture.

Journal of orthopaedic trauma·2023
Same author

Commentary on: Optimizing Orthopaedic Trauma Implant Pricing Through a Data-Driven and Surgeon-Integrated Approach.

Journal of orthopaedic trauma·2023
Same author

Commentary on: Advantages of a Dedicated Orthopaedic Trauma Operating Room for Diaphyseal Femur Fractures.

Journal of orthopaedic trauma·2021
Same author

Multidose prophylactic IV antibiotics do not lower the risk of surgical site infection for isolated closed ankle fractures.

OTA international : the open access journal of orthopaedic trauma·2021
Same journal

Functional Outcomes Following Bipolar Hip Hemiarthroplasty via the Direct Anterior Approach Versus Posterior and Direct Lateral Approaches: A Retrospective Cohort Study.

Journal of orthopaedic trauma·2026
Same journal

Preoperative High-Sensitivity Troponin and Risk of In-Hospital Mortality and Cardiac Events after Hip Fracture Surgery.

Journal of orthopaedic trauma·2026
Same journal

A Comprehensive Guide to Tibial Nailing Systems for Short Segment Nailing Procedures.

Journal of orthopaedic trauma·2026
Same journal

Minimally Invasive Screw Fixation of Olecranon Fractures.

Journal of orthopaedic trauma·2026
Same journal

Surgical Fixation Enhances Discharge Independence in Elderly Patients With Fragility Fractures of the Pelvis.

Journal of orthopaedic trauma·2026
Same journal

Intrapelvic Plate Fixation of Associated Both Column Acetabular Fracture in an Elderly Patient.

Journal of orthopaedic trauma·2026
See all related articles

Related Experiment Video

Updated: Dec 8, 2025

Monitoring Electroporation-Induced Changes in Action Potential Generation in Genetically Engineered Tet-On Spiking HEK cells
10:12

Monitoring Electroporation-Induced Changes in Action Potential Generation in Genetically Engineered Tet-On Spiking HEK cells

Published on: September 6, 2024

557

Another Type of Surge

Roy Sanders1

  • 1Editor-in-Chief.

Journal of Orthopaedic Trauma
|September 18, 2020
PubMed
Summary

No abstract available in PubMed .

More Related Videos

Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water
06:35

Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water

Published on: July 25, 2025

693
Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
04:35

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment

Published on: July 5, 2024

2.2K

Related Experiment Videos

Last Updated: Dec 8, 2025

Monitoring Electroporation-Induced Changes in Action Potential Generation in Genetically Engineered Tet-On Spiking HEK cells
10:12

Monitoring Electroporation-Induced Changes in Action Potential Generation in Genetically Engineered Tet-On Spiking HEK cells

Published on: September 6, 2024

557
Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water
06:35

Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water

Published on: July 25, 2025

693
Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
04:35

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment

Published on: July 5, 2024

2.2K