Related Experiment Video
Updated: Dec 8, 2025

High-resolution Structural Magnetic Resonance Imaging of the Human Subcortex In Vivo and Postmortem
Published on: December 30, 2015
A High-Resolution 1.3-GHz/54-mm LTS/HTS NMR Magnet
Yukikazu Iwasa1, Juan Bascuñán1, Seungyong Hahn1
1Francis Bitter Magnet Laboratory (FBML) of the Plasma Science and Fusion Center (PSFC), Massachusetts Institute of Technology (MIT), Cambridge, MA 02139 USA.
Abstract:
A high-resolution 1.3-GHz/54-mm low-temperature superconducting/high-temperature superconducting (HTS) nuclear magnetic resonance magnet (1.3 G) is currently in the final stage at the Massachusetts Institute of Technology Francis Bitter Magnet Laboratory. Its key component is a three-coil (Coils 1-3) 800-MHz HTS insert comprising 96 no-insulation (NI) double-pancake coils, each wound with a 6-mm-wide GdBCO tape. In this paper, after describing the overall 1.3-G system, we present innovative design features incorporated in 1.3 G: 1) an NI winding technique applied to Coils 1-3 and its adverse effect in the form of charging time delay; 2) persistent-mode HTS shims; 3) a "shaking" magnet; and 4) preliminary results of Coil 1 operated at 4.2 K.