Related Experiment Video
Updated: Dec 8, 2025

Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Detachable string magnetically controlled capsule endoscopy for complete observation of the upper gastrointestinal
Hui Xiu1, Yanyan Lu1, Xishuang Liu1
1Department of Gastroenterology.
Background:
Wireless magnetically controlled capsule endoscopy (WMCCE) was feasible, well tolerated, highly acceptable, and had high consistency in diagnosis of gastric diseases with esophagogastroduodenoscopy (EGD). But WMCCE is not suitable for inspection of the esophagus. We developed detachable string magnetically controlled capsule endoscopy (DS-MCCE) to observe gastroesophageal diseases.
Methods:
A total of 60 volunteers were enrolled. Thirty participants underwent DS-MCCE, and the other 30 underwent WMCCE. The primary outcome measures included swallowing time, esophageal transit time, the whole examination time, grade of air-bubble interference on esophageal, gastric preparation, visualization of Z-line and gastric mucosa, and discomfort scores.
Results:
The esophageal time (222.53 ± 107.53 s vs. 49.50 ± 34.90 s, P < 0.001) and the whole examination time (26.53 ± 6.33 min vs. 15.97±4.90 min, P < 0.001) in DS-MCCE group were longer than in WMCCE group. DS-MCCE had a significantly better visualization of Z-line visualization. Visualization of the gastric mucosa was assessed as good in 24 (80%) participants for DS-MCCE and 26 (86.6%) for WMCCE, moderate in 6 (20%) with DS-MCCE as compared with 4 (13.3%) with WMCCE. The visualization of gastric cardia for DS-MCCE was better than for WMCCE (100 vs 80%, P = 0.024). The visualization of gastric angle, antrum, and pylorus in DS-MCCE group was not as good as in WMCCE group (80 vs. 100%, 80 vs. 100%, 83.3 vs. 100%, P = 0.024).
Conclusions:
DS-MCCE is feasible and well tolerated in the diagnosis of gastroesophageal diseases. For people who cannot stand conventional EGD or with contraindication of EGD, DS-MCCE may be an excellent alternative screening modality.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures V: ERCP
Patient...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...