Related Experiment Video
Updated: Dec 8, 2025

3D Printing Model of a Patient's Specific Lumbar Vertebra
Published on: April 14, 2023
Development and validation of osteoligamentous lumbar spine under complex loading conditions: A step towards
Sagar Umale1, Narayan Yoganandan2, Shekar N Kurpad2
1Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI, USA.
Abstract:
Finite-element models are used to investigate the biomechanics of normal, diseased and surgically fused spines. Generally, nominal spine geometries are used to understand the biomechanics, which has created a need for a technique that develops patient-specific lumbar spine geometries. In the current study, a lumbar spine (T12-Sacrum) was developed using a technique that facilitates geometrical morphing, which assists in incorporating patient-specific morphologies into the model. The model evaluations can be used to propose a biomechanically suitable lumbar spine fusion procedure for patients. This study focuses on the validation of the base model under pure-moment, pure-compression and combined-compression-and-moment loadings. Experimental data from the literature were used to validate the response of the model. The L1-L2, L2-L3, L3-L4, L4-L5 and L5-sacrum segments demonstrated a range of motion of 4.5, 4.0, 5.4, 5.0 and 8.9° in flexion; 3.0, 2.5, 3.6, 3.1 and 5.2° in extension; 6.2, 5.8, 6.4, 5.0 and 6.1° in right and left lateral bending; and 2.9, 3.0, 2.9, 1.9 and 2.5° in right and left axial rotation, all under 10 Nm pure-moment loading. The L1-L2, L2-L3, L3-L4, L4-L5 and L5-sacrum discs demonstrated compressions of 1.1, 1.4, 1.6, 1.4 and 0.9 mm under 1200 N follower- or pure-compression loading. With the combined loading of 280 N follower and 7.5 Nm moment, the L1-L5 model demonstrated 11.7, 7.2, 18.3 and 10.4 degrees of range of motion in flexion, extension, bending and rotation, respectively. The model results were in good agreement with corridors from six different experimental studies and can be used for future clinical studies.
Related Concept Videos
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Normal Strain under Axial Loading
Eccentric Axial Loading in a Plane of Symmetry

