Related Experiment Video
Updated: Dec 8, 2025

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Determination of Mercury Content in Surface Waters Using an Environmentally Non-Toxic Terminating Electrolyte
Joanna Jabłońska1, Mariusz Kluska2
1Faculty of Exact and Natural Sciences, Siedlce University of Natural Sciences and Humanities, 54 3-Maja St, 08-110, Siedlce, Poland.
Abstract:
The paper presents results of the research on the dynamics of changes in the concentration of mercury in surface waters. The importance of mercury as an environmental pollutant results from specific properties of this metal, many sources of contamination, volatility, mobility, stability and high toxicity of its specific chemical forms. Samples of surface water collected from three rivers: the Bug, the Liwiec and the Muchawka were analysed. The Muchawka River flows into the Liwiec River, which in turn is a tributary of the Bug River. The technique of isotachophoresis was employed, using a solution of a biodegradable and environmentally non-toxic derivative of electrostatically stabilised silanates as the terminating electrolyte. The highest average mercury concentration of 0.89 μg/dm3 was determined in water samples collected from the Bug River in January, whereas the lowest concentration of 0.42 μg/dm3 was recorded in water collected from the Muchawka River in September.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.