Impacts of solar intermittency on future photovoltaic reliability

Jun Yin1, Annalisa Molini2,3, Amilcare Porporato4,5

  • 1School of Hydrology and Water Resources, Nanjing University of Information Science and Technology, Nanjing, 210044, China.

Nature Communications
|September 23, 2020
PubMed

Related Concept Videos

Distribution Reliability and Automation01:25

Distribution Reliability and Automation

Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
421
P-N junction01:11

P-N junction

A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
948
Instantaneous Power01:22

Instantaneous Power

Instantaneous power is important in electrical circuits, mainly when dealing with sinusoidal input. Instantaneous power, denoted as p(t), results from the multiplication of the instantaneous voltage (v(t)) across an element and the instantaneous current (i(t)) flowing through it. This relationship adheres to the passive sign convention and represents a fundamental principle in electrical engineering.
746
Conservation of AC Power01:15

Conservation of AC Power

The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
529
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
452
Power Factor Correction01:20

Power Factor Correction

The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
385