Related Experiment Video
Updated: Dec 8, 2025

Investigating the Potential of Singly Curved Thin Piezoelectric Transducers for Energy Harvesting and Structural Health Monitoring
Published on: November 14, 2025
Detecting of the Crack and Leakage in the Joint of Precast Concrete Segmental Bridge Using Piezoceramic Based Smart
Jianqun Wang1,2, Zhe Fan2,3
1Hunan Provincial Key Laboratory of Structures for Wind Resistance and Vibration Control, School of Civil Engineering, Hunan University of Science and Technology, Xiangtan 411201, China.
Abstract:
Precast concrete segmental bridges (PCSBs) have been widely used in bridge engineering due to their numerous competitive advantages. The structural behavior and health status of PCSBs largely depend on the performance of the joint between the assembled segments. However, due to construction errors and dynamic loading conditions, some cracks and leakages have been found at the epoxy joints of PCSBs during the construction or operation stage. These defects will affect the joint quality, negatively impacting the safety and durability of the bridge. A structural health monitoring (SHM) method using active sensing with a piezoceramic-based smart aggregate (SA) to detect the crack and leakage in the epoxy joint of PCSBs was proposed and the feasibility was studied by experiment in the present work. Two concrete prisms were prefabricated with installed SAs and assembled with epoxy joint. An initial defect was simulated by leaving a 3-cm crack at the center of the joint without epoxy. With a total of 13 test cases and the different lengths of cracks without water and filled with water were simulated and tested. Time-domain analysis, frequency-domain analysis and wavelet-packet-based energy index (WPEI) analysis were conducted to evaluate the health condition of the structure. By comparing the collected voltage signals, Power Spectrum Density (PSD) energy and WPEIs under different healthy states, it is shown that the test results are closely related to the length of the crack and the leakage in the epoxy joint. It is demonstrated that the devised approach has certain application value in detecting the crack and leakage in the joint of PCSBs.
Related Concept Videos
Microcracking in Concrete
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Preplaced Aggregate Concrete
Segregation in Fresh Concrete
Permeability of Concrete
Non-destructive Tests for Concrete Strength

