Related Experiment Video
Updated: Dec 8, 2025

Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
New Insights into the Chromatography Mechanisms of Ion-Exchange Charge Variant Analysis: Dispelling Myths and
Julia Baek1, Alexander B Schwahn2, Shanhua Lin1
1Thermo Fisher Scientific, 1228 Titan Way, Sunnyvale, California 94085, United States of America.
Abstract:
Charge variant analysis is a widely used analytical tool in characterization of monoclonal antibodies (mAbs). It depicts the heterogeneity of charge variant forms, some of which may differ by only minor modifications of a single amino acid. The analysis ensures product consistency with no unwanted changes to the protein. With increasing numbers of new mAb drug products emerging in the market, the need for a robust charge variant analysis has intensified. The charge variant profiles often display partially resolved peaks on shoulders of larger peaks. This puts considerably more pressure on the robustness of the method to maintain the suboptimum selectivity. New products and techniques have emerged to address these requirements, in addition to the pre-existing older methods that may not have been optimized correctly in the past. This has led to some confusion as to the best approach and strategies in optimization of charge variant analysis. We show studies from several different approaches using on-line pH monitoring to check the performance characteristics of the methods. This has led to new insights on the interactions between the protein, column, and buffer constituents. We dispel some inaccurate assumptions about the different ion-exchange elution mechanisms and suggest ways to develop high-throughput methods that remain robust and of high resolution. Streamlined automatable method development tools are presented that will result in more efficient method optimization. The mechanisms behind poor chromatography design have provided an alternative explanation behind some methods failing when in the QC laboratories.
Related Concept Videos
Ion-Exchange Chromatography
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Ion Exchange
High-Performance Liquid Chromatography: Elution Process
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...