Related Experiment Video
Updated: Dec 7, 2025

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Berlin Heart EXCOR Paediatric Ventricular Assist Device: Does Weight Matter?
Virginie Fouilloux1, Fedoua El Louali2, Célia Gran1
1Department of Paediatric and Congenital Cardiac Surgery, Timone Hospital, Marseille, France; Faculty of Medicine, Aix-Marseille University, Marseille, France.
Children needing mechanical circulatory support with the Berlin Heart EXCOR (BH) device face high mortality risks, with low body weight being a significant predictor. This study highlights key complications and survival rates in pediatric patients awaiting heart transplantation or recovery.
Area of Science:
- Pediatric Cardiology
- Mechanical Circulatory Support
- Cardiac Surgery
Background:
- The Berlin Heart EXCOR (BH) ventricular assist device offers mechanical long-term circulatory support for children with end-stage heart failure, serving as a bridge to transplantation or recovery.
- Existing research on BH devices primarily originates from high-volume pediatric cardiac centers.
Purpose of the Study:
- To analyze the experiences with BH devices across three French centers.
- To compare these findings with existing published data on pediatric ventricular assist devices.
Main Methods:
- A retrospective observational study was conducted across three pediatric cardiac intensive care units.
- Data on morbidity, mortality, and risk factors were collected for all children supported with BH devices.
Main Results:
- Survival rate while on BH support was 73% among 54 pediatric patients.
- Dilated cardiomyopathy was the primary indication (61%), with bi-ventricular assist device use in 46% of cases.
- Key complications included renal dysfunction (57%), bleeding (41%), and infection (39%). A weight below 5 kg was significantly associated with increased mortality.
Conclusions:
- Body weight appears to be the most critical risk factor for mortality in pediatric patients requiring BH device support.
- These findings underscore the importance of considering patient weight in managing pediatric end-stage heart failure with mechanical circulatory support.
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Heart Failure V: Medical Management
Mitral Stenosis III: Medical Management