Wearable Wireless-Enabled Oscillometric Sphygmomanometer: A Flexible Ambulatory Tool for Blood Pressure Estimation
Abstract:
This article presents the design of an unobtrusive and wireless-enabled blood pressure (BP) monitoring system that is suitable for ambulatory use. By adopting low-profile electromechanical actuators and a compact printed circuit board design, this lightweight device can be worn directly on the occlusive cuff, therefore eliminating the need of a long and obtrusive tubing interconnect between the device and the cuff, as seen in traditional ambulatory BP monitors (ABPM). Instead of executing the BP estimation algorithm directly on the device, the proposed design rather sends the raw oscillometric signal through a Bluetooth Low Energy link, thus granting any Bluetooth-enabled device to gather and process the signal using a dedicated application. This in turn allows to assess several BP estimation algorithms found in the literature without being limited by the device resources. Three of them were tested with the designed prototype and validated with a reference equipment on 11 subjects. Overall, two of the algorithms revealed a mean absolute difference with the reference equipment of less than 5 mmHg and almost zero bias along with a standard deviation of less than 6 mmHg. Reproducibility results shown a mean difference between successive measurements of less than 3.1 mmHg and a standard deviation of less than 2.4 mmHg. The assembled prototype dimensions are 63.8 × 134.8 × 24.8 mm and features an autonomy of 63.1 hours. Comparison with commercial ABPM devices shown that the proposed design is 18% to 33% smaller volume-wise, 5% to 27% weight-wise and height is reduced by 17% to 25%.
More Related Videos
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: