Related Experiment Video
Updated: Aug 7, 2026

Detection of Foodborne Bacterial Pathogens from Individual Filth Flies
Published on: February 13, 2015
Assessment of Data Sources That Support US Food and Drug Administration Medical Devices Safety Communications
Noam Tau1,2, Daniel Shepshelovich2,3
1Department of Diagnostic Imaging, Sheba Medical Center, Ramat Gan, Israel.
Importance:
Medical Device Safety Communications (MDSCs) are used by the US Food and Drug Administration (FDA) to convey important new safety information to patients and health care professionals. The sources of initial safety signals that trigger MDSCs have not been described previously.
Objective:
To assess the sources of initial safety signals that trigger publication of MDSCs and the potential associations among MDSC data source, type of safety issue, and subsequent FDA action.
Design, Setting, And Participants:
In this cross-sectional study, all MDSCs published on the FDA website between January 1, 2011, and December 31, 2019, were assessed. The MDSC characteristics, sources of initiating safety signals, regulatory approval or clearance pathways of the related medical devices, and subsequent FDA actions were collected from the FDA website.
Main Outcomes And Measures:
The main outcome was the distribution of sources of initial safety signals that led to publication of MDSCs. Secondary aims included exploration of potential associations among safety signal sources (direct reporting vs other), type of safety issue (death vs other), and FDA action (withdrawal vs other).
Results:
A total of 93 MDSCs were evaluated. Median time from device approval to MDSC posting was 10 years (interquartile range, 6-16 years). The most common data sources that triggered MDSCs were direct reports to the FDA through the Medical Device Reporting (MDR) program (44 of 93 [47%]) followed by regulator-initiated assessments (32 [34%]). Common safety issues included patient injury (25 [27%]), potential wrong diagnoses (19 [20%]), and death (18 [19%]). Frequent FDA action after MDSC posting included recommendation for increased vigilance and caution (47 [51%]), complete device withdrawal (12 [13%]), and warnings of specific lots or clinics (12 [13%]). There was a statistically significant correlation between direct reports of adverse events to the FDA through the MDR program and risk of death as a safety issue (14 of 44 [32%] for direct reporting vs 4 of 49 [8%] for any other data sources, P = .007).
Conclusions And Relevance:
In this cross-sectional study, the most common source of initial safety signals that triggered MDSCs was direct reports of real-world adverse events to the FDA through the MDR program. The delayed detection of postmarketing adverse events highlights the importance of proactive identification of emerging device-related safety issues.
More Related Videos
08:24Loop-Mediated Isothermal Amplification for Screening Salmonella in Animal Food and Confirming Salmonella from Culture Isolation
Published on: May 20, 2020
08:47Evaluation of Cardiac Contractility Modulation Therapy in 2D Human Stem Cell-Derived Cardiomyocytes
Published on: December 16, 2022
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Drug Regulation
FDA Approved Drugs: Changes to Approved Drugs
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Sources of Food Contamination
Investigation of Disease Outbreaks