Related Experiment Video
Updated: Dec 7, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Radiological implications of crestal and subcrestal implant placement in posterior areas. A cone-beam computed
Hilario Pellicer-Chover1, Julio Rojo-Sanchís2, Miguel Peñarrocha-Diago3
1DDS, PhD. Collaborating Professor of the Master of Oral Surgery and Implant Dentistry, Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Spain.
Background:
Subcrestal implant placement has been suggested as a method that could contribute to maintain the periimplant soft and hard tissues in comparison with crestal placement. The objective of this study was to investigate the relationship between implant placement at different depths in the alveolar bone and (a) the thickness of the buccal bone plate (BBP); and (b) crestal cortical bone thickness, based on the use of cone-beam computed tomography (CBCT).
Material And Methods:
A cross-sectional study was performed, analyzing CBCT scans from the database of the Oral Surgery Unit of the University of Valencia. Individuals with single missing teeth in posterior sectors were included. Two trained dentists used a software application to plan implant placement at four different depths from the bone crest (from 0-2 mm subcrestal). The thickness of the BBP was measured at each established depth, tracing a line from the implant platform to the outermost part of the facial alveolar bone, and the ratio between the implant platform and cortical bone thickness was calculated.
Results:
The study sample consisted of 64 patients. In the case of implants placed in a crestal position, the distance from the platform to the BBP was 1.99±1.10 mm. This distance increased significantly (p<0.001) with the planned implant placement depth, reaching an average of 2.90±1.22 mm when placement was 2 mm subcrestal. Subcrestal implant placement at this depth implied surpassing the cortical bone in 91% of the cases.
Conclusions:
Radiological planning of implant placement in a subcrestal position results in a greater distance from the implant platform to the BBP. In general terms, planning implant placement at a depth of 2 mm subcrestal surpassed the cortical bone in 91% of the cases. Key words:Subcrestal implant, cortical bone thickness, buccal bone plate, cone-beam computed tomography.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
09:10Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
X-ray Imaging