Related Experiment Video
Updated: Dec 7, 2025

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Preoperative multidetector computed tomography for isolated surgical aortic valve replacement: Planning for future
Craig Basman1, Karthik Seetharam1, Joel Johnson1
1Department of Cardiovascular and Thoracic Surgery, Lenox Hill Hospital/Northwell Health, New York, New York, USA.
Background:
Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has become a valuable option in patients with bioprosthetic failure. However, potential issues with ViV TAVR may occur in patients with high-risk anatomy for coronary obstruction and patients with baseline smaller bioprosthetic valves at risk for patient prosthesis mismatch. The purpose of this study was, therefore, to use preoperative electrocardiography-gated, multidetector computed tomography (MDCT) in patients undergoing isolated surgical aortic valve replacement (SAVR) to (1) identify which would be high risk for coronary occlusion with ViV TAVR, and (2) predict intraoperative SAVR sizing.
Methods:
Among 223 patients from our institutions' database that underwent SAVR for aortic insufficiency (AI) or aortic stenosis (AS) between January 2012 and January 2020, 48 patients had MDCT imaging before surgery (AI; n = 31, AS; n = 17). Of all patients, 67% (n = 32) were bicuspid morphology.
Results:
With the use of virtual valve implantation, all patients with AI and bicuspid AS had feasible anatomy for ViV TAVR, while 38% of patients with tricuspid AS were high risk for coronary obstruction. There was a strong correlation between actual valve size implanted and preoperative MDCT measurements using annulus average diameter, area, and/or perimeter.
Conclusion:
Preoperative MDCT in patients undergoing SAVR is a useful tool for lifetime management, particularly in patients with tricuspid AS. Decisions for surgical management may change based on MDCT's ability to predict intraoperative SAVR size and determine which patients may be high-risk candidates for future ViV TAVR due to coronary artery obstruction.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
08:50Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Aortic Regurgitation III: Medical Management
Aneurysm IV: Nursing Management