Related Experiment Video
Updated: Dec 6, 2025

Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
The predictive value of airway occlusion pressure at 100 msec (P0.1) on successful weaning from mechanical
Ryota Sato1, Daisuke Hasegawa2, Natsumi T Hamahata1
1Department of Internal Medicine, John A. Burns School of Medicine, University of Hawaii at Manoa, Honolulu, HI, USA.
Purpose:
The predictive value of airway occlusion pressure at 100 milliseconds (P0.1) on weaning outcome has been controversial. We performed a meta-analysis to investigate the predictive value of P0.1 on successful weaning from mechanical ventilation.
Materials And Methods:
We searched MEDLINE, Cochrane Central Register of Controlled Trials, and EMBASE, and two authors independently screened articles. The pooled sensitivity, specificity and the summary receiver operating characteristic (sROC) curve were estimated. Diagnostic odds ratio (DOR) was calculated using meta-regression analysis.
Results:
We included 12 prospective observational studies (n = 1089 patients). Analyses of sROC curves showed the area under the curve of 0.81 (95% confidence interval (CI): 0.77 to 0.84) for P0.1. The pooled sensitivity and specificity were 86% (95% CI, 72 to 94%) and 58% (95% CI, 37% to 76%) with substantial heterogeneity respectively. DOR was 20.09 (p = 0.019, 95%CI: 1.63-247.15). After filling the missing data using the trim-and-fill method to adjust publication bias, DOR was 36.23 (p = 0.002, 95%CI: 3.56-372.41).
Conclusion:
This meta-analysis suggests that P0.1 is a useful tool to predict successful weaning. To determine clinical utility, a large prospective study investigating the sensitivity and specificity of P0.1 on weaning outcomes from mechanical ventilation is warranted.
More Related Videos
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: