Related Experiment Video
Updated: Dec 6, 2025

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Improving Image Correlation and Differentiation of 3D Endoluminal Lesions in the Air Spaces Using a Novel Target Gray
Lih-Shyang Chen1, Ta-Wen Hsu2,3, Shao-Jer Chen3,4,5
1Department of Electric Engineering, National Cheng Kung University, Tainan, Taiwan, ROC.
Purpose:
To improve the three dimensional (3D) and two dimensional (2D) image correlation and differentiation of 3D endoluminal lesions in the traditional surface rendering (SR) computed tomographic endoscopy (CTE), a target gray level mapping (TGM) technique is developed and applied to computed tomographic colonography (CTC) in this study.
Methods:
A study of sixty-two various endoluminal lesions from thirty patients (13 males, 17 females; age range 31-90 years) was approved by our institutional review board and evaluated retrospectively. The endoluminal lesions were segmented using gray level threshold. The marching cubes algorithm was used to detect isosurfaces in the segmented volumetric data sets. TGM allows users to interactively apply grey level mapping (GM) to region of interest (ROI) in the 3D CTC. Radiologists conducted the clinical evaluation and the resulting data were analyzed.
Results:
TGM and GM are significantly superior to SR in terms of surface texture, 3D shape, the confidence of 3D to 2D, 2D to 3D image correlation, and clinical classification of endoluminal lesions (P < 0.01). The specificity and diagnostic accuracy of GM and TGM methods are significantly better than those of SR (P < 0.01). Moreover, TGM performs better than GM (specificity: 75.0-85.7% vs. 53.6-64.3%; accuracy: 88.7-93.5% vs. 77.4-83.9%). TGM is a preferable display mode for further localization and differentiation of a lesion in CTC navigation.
Conclusions:
Compared with only the spatial shape information in traditional SR of CTC images, the 3D shapes and gray level information of endoluminal lesions can be provided by TGM simultaneously. 3D to 2D image correlations are also increased and facilitated at the same time. TGM is less affected by adjacent colon surfaces than GM. TGM serves as a better way to improve the image correlation and differentiation of endoluminal lesions.
More Related Videos
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...