Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Glaucoma: Overview01:25

Glaucoma: Overview

1.1K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.1K
Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

987
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
987
Open Angle Glaucoma: Treatment01:27

Open Angle Glaucoma: Treatment

861
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
861

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Exploring the Effect of Race in Automated Skin Cancer Detection.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

Fuzzy-Label Weighted Deep Learning Classification for CT Image Quality Evaluation.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

Anatomical compensation of retinal nerve fiber layer improves the detection of glaucoma between ethnicities.

Annals of the New York Academy of Sciences·2024
Same author

Ocular microvascular complications in diabetic retinopathy: insights from machine learning.

BMJ open diabetes research & care·2024
Same author

Early Prediction of Wound Healing Outcome Based on Chronic Wound Registry Database.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2023
Same author

The Effectiveness of a Nurse-led Glaucoma Education on Patient Knowledge and Compliance Motivation Levels: A 1-year Prospective Case Series.

Journal of current glaucoma practice·2023
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
See all related articles

Related Experiment Video

Updated: Dec 6, 2025

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
07:11

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

Published on: May 25, 2020

6.7K

Automatic Glaucoma Detection from Stereo Fundus Images.

Ee Ping Ong, Jun Cheng, Damon W K Wong

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |October 6, 2020
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a novel method for automatic glaucoma detection using stereo fundus images. The approach accurately calculates the optic cup-to-disc ratio for early glaucoma diagnosis.

    More Related Videos

    Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
    07:22

    Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases

    Published on: March 11, 2016

    11.7K
    High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning
    09:31

    High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning

    Published on: April 28, 2022

    3.4K

    Related Experiment Videos

    Last Updated: Dec 6, 2025

    Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
    07:11

    Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential

    Published on: May 25, 2020

    6.7K
    Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
    07:22

    Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases

    Published on: March 11, 2016

    11.7K
    High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning
    09:31

    High-Speed Ultraviolet Photoacoustic Microscopy for Histological Imaging with Virtual-Staining assisted by Deep Learning

    Published on: April 28, 2022

    3.4K

    Area of Science:

    • Ophthalmology
    • Medical Imaging
    • Computer Vision

    Background:

    • Glaucoma is a leading cause of irreversible blindness worldwide.
    • Early detection is crucial for managing glaucoma and preventing vision loss.
    • Accurate measurement of the optic cup-to-disc area ratio is a key diagnostic indicator.

    Purpose of the Study:

    • To develop and validate a new automated method for glaucoma detection.
    • To accurately segment the optic cup and optic disc from stereo fundus images.
    • To calculate the optic cup-to-disc area ratio for glaucoma diagnosis.

    Main Methods:

    • Utilizing stereo fundus image pairs to estimate a disparity map.
    • Segmenting the optic disc from a single fundus image.
    • Employing active contour segmentation on the disparity map to isolate the optic cup.
    • Calculating the optic cup-to-disc area ratio based on segmented regions.

    Main Results:

    • The proposed method demonstrates efficacy in automatic glaucoma detection.
    • Accurate segmentation of optic cup and disc was achieved.
    • The optic cup-to-disc area ratio was reliably computed.

    Conclusions:

    • The developed method offers a promising automated approach for glaucoma screening.
    • This technique can aid ophthalmologists in early glaucoma diagnosis.