Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Covariance intersection to improve the robustness of the photoplethysmogram derived respiratory rate
Abstract:
Respiratory rate (RR) can be estimated from the photoplethysmogram (PPG) recorded by optical sensors in wearable devices. The fusion of estimates from different PPG features has lead to an increase in accuracy, but also reduced the numbers of available final estimates due to discarding of unreliable data. We propose a novel, tunable fusion algorithm using covariance intersection to estimate the RR from PPG (CIF). The algorithm is adaptive to the number of available feature estimates and takes each estimates' trustworthiness into account. In a benchmarking experiment using the CapnoBase dataset with reference RR from capnography, we compared the CIF against the state-of-the-art Smart Fusion (SF) algorithm. The median root mean square error was 1.4 breaths/min for the CIF and 1.8 breaths/min for the SF. The CIF significantly increased the retention rate distribution of all recordings from 0.46 to 0.90 (p < 0.001). The agreement with the reference RR was high with a Pearson's correlation coefficient of 0.94, a bias of 0.3 breaths/min, and limits of agreement of -4.6 and 5.2 breaths/min. In addition, the algorithm was computationally efficient. Therefore, CIF could contribute to a more robust RR estimation from wearable PPG recordings.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...