Related Experiment Video
Updated: Dec 6, 2025

Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy
Published on: June 16, 2022
Management of incontinence following pre-pubic urethrostomy in a cat using an artificial urethral sphincter
1Anderson Moores Veterinary Specialists, Poles Lane, Winchester, Hampshire, SO21 2LL, UK.
Abstract:
A 14-year-old male neutered domestic shorthair cat presented with a 4-year history of urinary incontinence following prepubic urethrostomy. Physical examination confirmed peristomal dermatitis, urine scalding and constant urine leakage. Haematology, serum biochemistry and urinalysis were unremarkable. Ultrasonography revealed a non-distended urinary bladder. An artificial urethral sphincter mechanism, with subsequent incremental inflation of the cuff 6 weeks later, resulted in complete resolution of clinical signs, return to normal urinary function and excellent quality of life. The cat was still continent at 5-year follow-up. Further studies including additional cases are required to highlight effectiveness and harms of the procedure.
Related Concept Videos
Anatomy of the Genitourinary System II: Bladder and Urethra
Urinary Tract Calculi VI: Surgical Management