Related Experiment Video
Updated: Dec 6, 2025

On-chip Isotachophoresis for Separation of Ions and Purification of Nucleic Acids
Published on: March 2, 2012
Capillary zone electrophoresis of proteins applying ionic liquids for dynamic coating and as background electrolyte
Emerencia Mező1, Csilla Páger1,2, Lilla Makszin1
1Institute of Bioanalysis, Medical School, and Szentágothai Research Center, University of Pécs, Pécs, Hungary.
Abstract:
The use of ionic liquids in capillary electrophoresis, either as coating material or as components of the background electrolyte needs systematic standardization to set up optimal conditions. Excellent separation of the proteins was achieved using 1-ethyl-3-methylimidazolium tetrafluoroborate ([emim][BF4]) or 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF4]) ionic liquids using the properly made ionic-liquid-water binary mixtures for the experiments. The binary mixture has a distinctly stable and well perceptible low pH, which depends on the concentration of the ionic liquid, and on the preparation time of the mixture. Optimal conditions for the electrophoretic separation were obtained upon a multivariate analysis of the experimental parameters (applied voltage, migration time, concentration, and type of the ionic liquid). The standardized condition provides a low electroendosmotic flow toward the anode, which, however, did not hinder the proteins to migrate toward the cathode. The migration of cytochrome c, lysozyme, myoglobin, trypsin, and apo-transferrin at a pH around 2, far below the isoelectric points of the proteins, showed RSD values of the migration times less than 7.5% and less than 6.5% when using [emim][BF4] or [bmim][BF4], respectively, either in run-to-run or day-to-day experiments. The determination of the extent of the EOF is not possible with the commonly used EOF markers, due to interaction with the ionic-liquid constituents. The interaction of the ionic liquids with the proteins influences the migration order in zone electrophoresis. This method has been applied successfully for the analyses of real biological samples such as proteins from egg whites and human tears.
More Related Videos
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
Electrophoresis: Overview
There...
Ion-Exchange Chromatography
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...

