Background:
The goal of this article was to report the results about the efficacy of treatment of chronic mesh infection (CMI) after abdominal wall hernia repair (AWHR) in one-stage management, with complete mesh explantation of infected prosthesis and simultaneous reinforcement with a biosynthetic poly-4-hydroxybutyrate absorbable (P4HB) mesh.
Methods:
This is a retrospective analysis of all patients that needed mesh removal for CMI between September 2016 and January 2019 at a tertiary center. Epidemiological data, hernia characteristics, surgical, and postoperative variables (Clavien-Dindo classification) of these patients were analyzed.
Results:
Of the 32 patients who required mesh explantation, 30 received one-stage management of CMI. In 60% of the patients, abdominal wall reconstruction was necessary after the infected mesh removal: 8 cases (26.6%) were treated with Rives-Stoppa repair, 4 (13.3%) with a fascial plication, 1 (3.3%) with anterior component separation, and 1 (3.3%) with transversus abdominis release to repair hernia defects. Three Lichtenstein (10%) and 1 Nyhus repairs (3.3%) were performed in patients with groin hernias. The most frequent postoperative complications were surgical site occurrences: seroma in 5 (20%) patients, hematoma in 2 (6.6%) patients, and wound infection in 1 (3.3%) patient. During the mean follow-up of 34.5 months (range 23-46 months), the overall recurrence rate was 3.3%. Persistent, recurrent, or new CMIs were not observed.
Conclusions:
In our experience, single-stage management of CMI with complete removal of infected prosthesis and replacement with a P4HB mesh is feasible with acceptable results in terms of mesh reinfection and hernia recurrence.