Mobile health applications for the detection of atrial fibrillation: a systematic review
Carlos Ruben Lopez Perales1,2, Harriette G C Van Spall3, Shingo Maeda4
1Department of Cardiology, Hopital Erasme, Université Libre de Bruxelles, Route de Lennik 808, 1070 Brussels, Belgium.
Aims:
Atrial fibrillation (AF) is the most common sustained arrhythmia and an important risk factor for stroke and heart failure. We aimed to conduct a systematic review of the literature and summarize the performance of mobile health (mHealth) devices in diagnosing and screening for AF.
Methods And Results:
We conducted a systematic search of MEDLINE, Embase, and the Cochrane Central Register of Controlled Trials. Forty-three studies met the inclusion criteria and were divided into two groups: 28 studies aimed at validating smart devices for AF diagnosis, and 15 studies used smart devices to screen for AF. Evaluated technologies included smartphones, with photoplethysmographic (PPG) pulse waveform measurement or accelerometer sensors, smartbands, external electrodes that can provide a smartphone single-lead electrocardiogram (iECG), such as AliveCor, Zenicor and MyDiagnostick, and earlobe monitor. The accuracy of these devices depended on the technology and the population, AliveCor and smartphone PPG sensors being the most frequent systems analysed. The iECG provided by AliveCor demonstrated a sensitivity and specificity between 66.7% and 98.5% and 99.4% and 99.0%, respectively. The PPG sensors detected AF with a sensitivity of 85.0-100% and a specificity of 93.5-99.0%. The incidence of newly diagnosed arrhythmia ranged from 0.12% in a healthy population to 8% among hospitalized patients.
Conclusion:
Although the evidence for clinical effectiveness is limited, these devices may be useful in detecting AF. While mHealth is growing in popularity, its clinical, economic, and policy implications merit further investigation. More head-to-head comparisons between mHealth and medical devices are needed to establish their comparative effectiveness.
More Related Videos
28:13Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Dysrhythmias V: Evaluating Dysrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias