Related Experiment Video
Updated: Dec 6, 2025

On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Critical review and re-assessment of analyte protectants in gas chromatography
Ruth Rodríguez-Ramos1, Steven J Lehotay2, Nicolás Michlig3
1Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avenida Astrofísico Francisco Sánchez, s/n. 38206 San Cristóbal de La Laguna (Tenerife), España.
Abstract:
Despite nearly 80 years of advancements in gas chromatography (GC), indirect chemical matrix effects (MEs), known as the matrix-induced response enhancement effect, still occur to cause a high bias in the GC analysis of susceptible analytes, unless precautions are taken. Matrix-matched calibration is one common option used in GC to compensate for the MEs, but this approach is usually inconvenient, imprecise, and inefficient. Other options, such as the method of standard additions, surface deactivation techniques, chemical derivatizations, priming the GC, and/or use of internal standards, also have flaws in practice. When methods are accommodating, the use of analyte protectants (APs) can provide the best practical solution to not only overcome MEs, but also to maximize analyte signal by increasing chromatographic and detection efficiencies for the analytes. APs address the source of MEs in every injection by filling active sites in the GC inlet, column, and detector, particularly in GC-MS, rather than the analytes that would otherwise undergo degradation, peak tailing, and/or diminished response due to interactions with the active sites. The addition of an adequate amount of APs (e.g. sugar derivatives) to all calibration standards and final extracts alike often leads to lower detection limits, better accuracy, narrower peaks, and greater robustness than the other options to compensate for MEs in GC. This article consists of a critical review of the scientific literature, proposal of mechanisms and theory, and re-evaluation studies involving APs for the first time in GC-orbitrap and GC-MS/MS with a high-efficiency ion source design. The findings showed that 1 µg each of co-injected shikimic acid and sorbitol in the former case, and 1 µg shikimic acid alone in the latter case, led to high quality results in multi-residue analysis of pesticides and environmental contaminants.
More Related Videos
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...