Related Experiment Video
Updated: Dec 6, 2025

Seeding and Implantation of a Biosynthetic Tissue-engineered Tracheal Graft in a Mouse Model
Published on: April 1, 2019
The History of Engineered Tracheal Replacements: Interpreting the Past and Guiding the Future
Allison M Greaney1, Laura E Niklason1,2
1Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.
Abstract:
The development of a tracheal graft to replace long-segment defects has thwarted clinicians and engineers alike for over 100 years. To better understand the challenges facing this field today, we have consolidated all published reports of engineered tracheal grafts used to repair long-segment circumferential defects in humans, from the first in 1898 to the most recent in 2018, totaling 290 clinical cases. Distinct trends emerge in the types of grafts used over time, including repair using autologous fascia, rigid tubes of various inert materials, and pretreated cadaveric allografts. Our analysis of maximum clinical follow-up, as a proxy for graft performance, revealed that the Leuven protocol has a significantly longer clinical follow-up time than all other methods of airway reconstruction. This method involves transplanting a cadaveric tracheal allograft that is first prevascularized heterotopically in the recipient. We further quantified graft-related causes of mortality, revealing failure modes that have been resolved, and those that remain a hurdle, such as graft mechanics. Finally, we briefly summarize recent preclinical work in tracheal graft development. In conclusion, we synthesized top clinical care priorities and design criteria to inform and inspire collaboration between engineers and clinicians toward the development of a functional tracheal replacement graft. Impact statement The field of tracheal engineering has floundered in recent years due to multiple article retractions. However, with recent advances in biofabrication and tissue analysis techniques, the field remains ripe for advancement through collaboration between engineers and clinicians. With a long history of clinical application of tracheal replacements, engineered tracheas are arguably the regenerative technology with the greatest potential for translation. This work describes the many phases of engineered tracheal replacements that have been applied in human patients over the past 100 years with the goal of carrying forward critical lessons into development of the next generation of engineered tracheal graft.
More Related Videos
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...