Diaphragm dysfunction detected with ultrasound to predict noninvasive mechanical ventilation failure: A prospective
Huseyin Kocyigit1, Muge Gunalp2, Sinan Genc2
1Diyarbakir Selahaddin Eyyubi State Hospital, Department of Emergency Medicine, Diyarbakir, Turkey.
Objective:
This study aimed to examine the use of point-of-care ultrasonography (POCUS) in detecting diaphragmatic dysfunction (DD) and evaluate its ability to predict noninvasive mechanical ventilation (NIV) failure in patients presented to the emergency department with acute exacerbation of chronic obstructive pulmonary disease (AECOPD).
Methods:
In this prospective cohort study, the diaphragm was examined using POCUS in patients with AECOPD. DD was defined as a diaphragm thickening fraction of less than 20% during spontaneous breathing. NIV failure was the primary outcome of the study, and duration of hospital stay and in-hospital mortality were the secondary outcomes. Specificity, sensitivity, positive predictive value, and negative predictive value were estimated for predicting NIV failure in DD and evaluating the diagnostic performance of POCUS.
Results:
60 patients were enrolled the study. NIV failure was found in 11 (73.3%) of 15 patients with DD and in 2 (4.4%) of 45 patients without DD. In predicting NIV failure, DD had a sensitivity of 84.6% (95% confidence interval [CI]:54.6-98.1), specificity of 91.5% (95% CI:79.6-97.6), positive predictive value of 73.3% (95% CI:51.2-87.8), and negative predictive value of 95.6% (95% CI:85.7-98.7). The duration of hospital stay was not different between groups (p = .065). No in-hospital mortality was seen in patients without DD.
Conclusions:
DD has high sensitivity and specificity in predicting NIV failure in patients admitted to the emergency department with AECOPD. DD can be assessed by an experienced clinician noninvasively using POCUS in emergency departments.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History