Related Experiment Video
Updated: Dec 6, 2025

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
In NPH, setting valve opening pressure close to lumbar puncture opening pressure decreases overdrainage
Tito Vivas-Buitrago1, Ricardo Domingo1, Shashwat Tripathi2
1Mayo Clinic, 4500 san pablo rd, 32224 Jacksonville, United States.
Background:
The management of normal pressure hydrocephalus (NPH) can be difficult, partly because there are frequent treatment complications such as overdrainage which, when serious, may require surgical intervention. We previously reported a correlation between the difference of lumbar puncture opening pressure minus the valve opening pressure setting (LPOP-VOP) (which we refer to as the delta) and increased rates of overdrainage. This led to a modification in our practice, whereby we now set the VOP equal to, or close to, the LPOP, resulting in lower deltas.
Objective:
In this new study, our aim was to compare the rate of overdrainage in our patients with higher and lower deltas and assess the significance of setting the VOP equal, or close, to the patient's LPOP.
Methods:
1. We reproduced the association between delta and overdrainage. 2. We compared the incidence of overdrainage in those whose VOP was set close to LPOP (low delta) versus those with VOP setting distant from the LPOP (higher delta). 3. We compared symptom improvement in those with a low versus higher delta.
Results:
We confirmed the relation between high delta and an increased rate of overdrainage, lower rates of overdrainage in those whose VOP was set close to the LPOP (Delta Adjusted Practice), and better improvement of symptoms when the VOP was set closer to the LPOP.
Conclusion:
We propose that the initial VOP should be set as close as possible to the patient's LPOP to decrease overdrainage without compromising symptom improvement.
Related Concept Videos
Aneurysm IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Peritoneal Dialysis III: Nursing Management
Glomerular Filtration: Net Filtration Pressure
GBHP, with an average value of 55 mmHg, promotes filtration by pushing water and solutes through the filtration membrane. This is balanced by two opposing forces: CHP, a "back pressure" exerted against the filtration membrane by fluid already in the capsular space and renal...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement