Mining urban sustainable performance: Spatio-temporal emission potential changes of urban transit buses in

Yi Sui1,2,3, Haoran Zhang4,2, Wenlong Shang5

  • 1College of Computer Science and Technology, Qingdao University, Ningxia Road No. 308, Qingdao 266071, China.

Applied Energy
|October 14, 2020
PubMed

Related Concept Videos

Design Example: Sustainability in Concrete Building01:26

Design Example: Sustainability in Concrete Building

As the construction industry moves towards more eco-friendly practices, concrete's adaptability and its ability to incorporate sustainable features make it a key material in the drive towards greener building solutions.
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
305
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
411
Effects of Air-entrainment in Concrete01:28

Effects of Air-entrainment in Concrete

Air entrainment in concrete significantly enhances the material's durability, especially in environments subjected to freeze-thaw cycles. Introducing small air bubbles into the concrete mix acts as internal voids that accommodate the expansion of water when it freezes, thereby alleviating internal stress and preventing structural cracks. This function is crucial in climates with significant freezing and thawing, as it protects the concrete from repeated stresses that could lead to premature...
264
Turnover Number and Catalytic Efficiency01:19

Turnover Number and Catalytic Efficiency

The turnover number of an enzyme is the maximum number of substrate molecules it can transform per unit time. Turnover numbers for most enzymes range from 1 to 1000 molecules per second. Catalase has the known highest turnover number, capable of converting up to 2.8×106 molecules of hydrogen peroxide into water and oxygen per second. Lysozyme has the lowest known turnover number of half a molecule per second.
Chymotrypsin is a pancreatic enzyme that breaks down proteins during digestion....
19.0K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
1.2K