Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
A systematic investigation of comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry with
Sonia Schöneich1, Timothy J Trinklein1, Cable G Warren1
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA, 98195, USA.
Abstract:
Dynamic pressure gradient modulation (DPGM) in full modulation mode is optimized for comprehensive two-dimensional (2D) gas chromatography (GC × GC) with time-of-fight mass spectrometry (TOFMS) detection to obtain high peak capacity separations and demonstrate broad applicability for complex samples. A pulse valve introduces an auxiliary carrier gas flow at a T-union connecting the first dimension (1D) column to the second dimension (2D) column. At a sufficiently high auxiliary pressure (Paux) the 1D flow is temporarily stopped. Then, during each modulation period (PM) the valve is turned off briefly, a period termed the pulse width (pw), allowing the 1D effluent to essentially be reinjected onto the 2D column for the modulated separations. Modifications to the modulator assembly are provided to improve performance. Method optimization is demonstrated for a 116-component test mixture by tuning the Paux and the pw. For a PM = 2 s and 1F of 0.10 ml/min, the optimal pw and initial Paux selected were 200 ms and 330.9 kPa (33 psig), respectively. The 30 min separation of the test mixture provided a 1D peak capacity of 1nc = 330 and a 2D peak capacity of 2nc = 15, hence an ideal 2D peak capacity nc,2D = 1nc × 2nc = 4950. Likewise, the 2D peak capacity corrected for undersampling of the 1D separation was 4500 and corrected for both undersampling and sampling variation via statistical overlap theory was 4090. These results provide a 2-fold improvement in peak capacity relative to the previous DPGM study in full modulation mode for GC × GC-TOFMS. The optimized conditions were applied for a variety of applications: diesel fuel, derivatized cow serum, solid phase microextraction (SPME) of coffee headspace, and SPME of river water headspace. Additionally, the fraction of 2D separation space utilized (fcoverage), as defined by the minimum convex hull method, ranged from 0.60 to 0.85. We observed that any fcoverage correction to 2D peak capacity is highly sample dependent, since all samples, except for the diesel sample, were run with the same separation conditions, and yet the fcoverage ranged from 0.60 to 0.80.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...