Related Experiment Video
Updated: Dec 5, 2025

A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Biomechanical Comparison of External Fixation and Double Plating for Stabilization of a Canine Cadaveric
Sarah Castaldo1, Jason Syrcle1, Steve Elder2
1Department of Clinical Sciences, College of Veterinary Medicine, Mississippi State University, Mississippi State, Mississippi, United States.
Objective:
Successful stabilization of comminuted supracondylar humeral fractures is challenging, and biomechanical studies are scarce. This study compares double-plate (DB-PLATE) and linear external fixator with an intramedullary pin tie-in (ESF-IMP) fixation techniques in a cadaveric gap model. The hypothesis was the DB-PLATE construct would be stiffer, stronger and more resistant to repeated loading than the ESF-IMP construct in both cyclic and load-to-failure axial compression testing.
Study Design:
A 2 cm ostectomy was performed on 10 pairs of canine cadaveric humeri proximal to the supratrochlear foramen. Stabilization was with DB-PLATE (n = 10) or ESF-IMP (n = 10). Cyclic testing was performed by applying a 200 N load at 2 Hz for 63,000 cycles. Axial compressive load to failure testing followed. Data analysed included dynamic stiffness, stiffness and yield load.
Results:
No constructs failed during cyclic testing or lost stiffness over time. Mean dynamic stiffness over the final 100 cycles was greater for DB-PLATE compared with ESF-IMP. Mean stiffness of DB-PLATE in load-to-failure testing was not different than ESF-IMP. Yield load of DB-PLATE was higher than ESF-IMP.
Conclusion:
Both DB-PLATE and ESF-IMP survived cyclic testing with no change in dynamic stiffness. DB-PLATE was stronger than ESF-IMP in load-to-failure testing, which may make this construct preferable when prolonged healing or poor patient compliance is anticipated. Results suggest that either method may be appropriate for fixation of comminuted supracondylar humeral fractures.
More Related Videos
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator