Related Experiment Video
Updated: Dec 5, 2025

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
An ultrasensitive non-noble metal colorimetric assay using starch-iodide complexation for Ochratoxin A detection
Akkapol Suea-Ngam1, Leif-Thore Deck1, Philip D Howes1
1Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, 8093, Zürich, Switzerland.
Abstract:
Colorimetric sandwich-type biosensors that can both provide sensitivity competitive with fluorescence-based approaches, and leverage reagents that are cost-effective, widely available and as safe as possible, are highly sought after. Herein, we demonstrate an alternative highly-sensitive colorimetric method for paper-based sandwich-type biosensing that uses starch-iodide complexation to simplify practical biosensing using ubiquitous reagents. Targeting the mycotoxin ochratoxin A (OTA), a covalently-immobilised OTA antibody on a cellulose surface captures OTA and forms a sandwich with OTA aptamer-conjugated glucose oxidase. Adding the chromogenic reagents at an optimized concentration, a distinct blue color develops within 30 min, offering excellent contrast with the clear/white of the negative sample. With a sampling volume down to just 5 μL, the assay exhibits concentration limits of detection and quantitation of 20 and 320 pg mL-1, respectively, and a linear range from 10-1 to 105 ng mL-1 (R2 = 0.997). The method displays excellent selectivity against related mycotoxins, excellent %recovery (95-117%) and robust operation in complex matrices (beer, urine and human serum), with no significant difference versus gold-standard liquid chromatography. Along with its excellent analytical performance, this assay benefits from non-toxic and extremely cheap reagents that can be safely disposed of in the field, and presents an attractive alternative to toxic dyes and nanoparticles.
More Related Videos
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Redox Titration: Overview
Complexometric Titration: Overview
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...

