Related Experiment Video
Updated: Dec 5, 2025

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Nail Versus Plate: A Biomechanical Comparison of a Locking Plate Versus an Intramedullary Nail With an Angular Stable
Susanne Strasser1, Franz Kralinger2, Michael Blauth3
1Department for Orthopedic Surgery, Medical University of Innsbruck, Innsbruck, Austria.
Objectives:
To compare a locking compression plate versus an intramedullary nail with an angular stable locking system (ASLS) using a 2-part fracture model in a shoulder test bench.
Methods:
Twelve fresh frozen humeri were used for biomechanical testing in a shoulder simulator. A 2-part fracture model, with and without medial cortical support, was used to compare the locking plate and a nail with an ASLS. The varus impaction, varus per cycle motion, tilt, and tilt per cycle were analyzed.
Results:
No significant differences for the resulting forces in the glenoid fossa were evaluated. The stable fracture model showed no significant differences for the 2 groups. The median varus impaction was -0.96 degrees (range -0.55 to -4.26 degrees) in the plate group and 0.5 degrees (range -3.06 to 0.98 degrees) in the nail group, after 500 cycles of cyclic loading in the unstable fracture model. The plate group showed a significantly higher median varus impaction per cycle motion and median varus impaction at the 200th, 300th, and 400th cycle of physiological loading.
Conclusions:
The intramedullary nail with the ASLS could be an alternative for patients suffering from osteoporosis and comorbidities.
More Related Videos
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025