Background:
Isolation gowns are one of the crucial pieces of personal protective equipment (PPE) to prevent the migration of microorganisms and body fluids from patients to health care personnel and vice versa. Underperforming isolation gowns in terms of fluid resistance, could potentially put lives in danger. Wearing multiple layers of isolation gowns could theoretically increase the fluid penetration resistance. This study investigates if 2-layer lower barrier level isolation gowns meet the barrier effectiveness requirements of a single higher barrier level isolation gown.
Methods:
Three commonly used ANSI/AAMI Level 2 isolation gown models were selected and tested in single layer and double layer configurations in accordance with ANSI/AAMI PB70 requirements.
Results:
Total of 240 experiments were conducted to analyze the effects of gown model, fabric region, and the number of gown layers on AATCC 127 and AATCC 42 test results. In regard to AATCC 42, there was a significant difference among the different gown models, and the number of gown layers. Similar to AATCC 42 results, there was a significant difference among the different gown models, and the number of gown layers for AATCC 127; additionally, the gown regions was also significantly different.
Conclusion:
Test results demonstrated that the double layer isolation gown configurations do not always provide equal fluid penetration resistance as required for a single Level 3 isolation gown using the standard test methods specified in ANSI/AAMI PB70.
Related Concept Videos
PPE Use in Healthcare Settings II: Doffing
Personal Protective Equipment
PPE Use in Healthcare Settings I: Donning
Surface Membrane Barriers
The outer layer of the skin, the epidermis, is a robust barrier comprising layers of closely packed keratinized cells. This dense arrangement prevents microbes from penetrating the body. The periodic shedding of epidermal cells...
Physiological Barriers
The blood endothelial barrier is the most porous of these. It allows all small ionized, un-ionized, and lipophilic molecules to pass through the endothelial lining into the interstitial space...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...