Helping to know if you are properly protected while working in interventional cardiology
E Vano1,2, Sanchez Casanueva Rm1,2, Fernandez Soto Jm2
1Radiology Department, Faculty of Medicine. Complutense University, E-28040 Madrid, Spain.
Abstract:
Occupational protection is still a challenge for interventional cardiology. One of the main problems is the occasional improper use of the ceiling suspended screen. We present a methodology to audit the correct use of the shielding using active electronic dosimeters. To improve the protection, we suggest the use of an alert based on the ratio between the occupational dose per procedure, measured by a personal electronic dosimeter over the lead apron, and the dose measured by an unshielded dosimeter, located at the C-arm. The new electronic dosimeters and the automatic dose management systems allow processing the dosimetric data for individual procedures and for the radiation events, sending the values (wireless) to a central database. We selected six interventional cardiologists and analysed 385 interventional procedures involving about 30 000 radiation events. Our results suggest that for individual procedures, standard values of the ratio between operator dose and the C-arm reference dose, should be between 1%-2% for a proper use of the shielding. Percentage values ≥5%-10% for individual procedures, require an analysis of the different radiation events to identify the lack of occupational protection and suggest corrective actions. In our sample, half of the operators should improve the use of the shielding in around 20% of the procedures. Using this ratio as an alert to operators allows optimising occupational radiation protection and discriminating between high occupational doses derived from complex procedures and high doses due to the improper use of the protective screen.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization IV: Nursing Management
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization III: Left Heart Catheterization
Coronary Artery Disease V: Interprofessional Care