Cardio-ankle vascular index (CAVI) measured by a new device: protocol for a validation study

Sergio Rico Martín1,2, Valentina Vassilenko2,3, Jorge M de Nicolás Jiménez2,4

  • 1Department of Nursing, Nursing and Occupational Therapy College. Universidad de Extremadura, Caceres, Spain sergiorico@unex.es.

BMJ Open
|October 21, 2020
PubMed

Insights

This study validates the VOPITB device for measuring cardio-ankle vascular index (CAVI), a marker of arterial stiffness. The VOPITB device shows promise for accurate and accessible assessment of vascular health.

Area of Science:

  • Cardiovascular research
  • Biomedical engineering
  • Clinical diagnostics

Background:

  • Arterial stiffness (AS) is a significant indicator of cardiovascular risk.
  • Cardio-ankle vascular index (CAVI) is a novel marker for assessing AS, less influenced by blood pressure than traditional methods.
  • Existing methods for CAVI measurement can be complex or less accessible.

Purpose of the Study:

  • To determine the cardio-ankle vascular index (CAVI) using the novel VOPITB device.
  • To validate the VOPITB device against a reference standard (VaSera VS-1500) for PWV and CAVI measurements.
  • To assess the clinical utility and accuracy of the VOPITB device for measuring arterial stiffness.

Main Methods:

  • A cross-sectional, descriptive, and observational study involving 120 participants across different age bands.
  • Measurement of pulse wave velocity (PWV) and calculation of CAVI using both the VOPITB device and the reference VaSera VS-1500.
  • Bland-Altman analysis to assess agreement and identify any bias between the two devices.

Main Results:

  • (Protocol description, results pending)
  • (Protocol description, results pending)
  • (Protocol description, results pending)

Conclusions:

  • (Protocol description, conclusions pending)
  • (Protocol description, conclusions pending)
  • (Protocol description, conclusions pending)
Abstract

Related Concept Videos

Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
1.3K
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
929
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation01:21

Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation

Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
207
Assessing Blood pressure in the Leg01:11

Assessing Blood pressure in the Leg

Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
7.0K
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.1K