A comparative study of trabecular bone micro-structural measurements using different CT modalities
Indranil Guha1, Benjamin Klintström2, Eva Klintström3
1Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America.
Abstract:
Osteoporosis, characterized by reduced bone mineral density and micro-architectural degeneration, significantly enhances fracture-risk. There are several viable methods for trabecular bone micro-imaging, which widely vary in terms of technology, reconstruction principle, spatial resolution, and acquisition time. We have performed an excised cadaveric bone specimen study to evaluate different computed tomography (CT)-imaging modalities for trabecular bone micro-structural analysis. Excised cadaveric bone specimens from the distal radius were scanned using micro-CT and fourin vivoCT imaging modalities: high-resolution peripheral quantitative computed tomography (HR-pQCT), dental cone beam CT (CBCT), whole-body multi-row detector CT (MDCT), and extremity CBCT. A new algorithm was developed to optimize soft thresholding parameters for individualin vivoCT modalities for computing quantitative bone volume fraction maps. Finally, agreement of trabecular bone micro-structural measures, derived from differentin vivoCT imaging, with reference measures from micro-CT imaging was examined. Observed values of most trabecular measures, including trabecular bone volume, network area, transverse and plate-rod micro-structure, thickness, and spacing, forin vivoCT modalities were higher than their micro-CT-based reference values. In general, HR-pQCT-based trabecular bone measures were closer to their reference values as compared to otherin vivoCT modalities. Despite large differences in observed values of measures among modalities, high linear correlation (rε [0.94 0.99]) was found between micro-CT andin vivoCT-derived measures of trabecular bone volume, transverse and plate micro-structural volume, and network area. All HR-pQCT-derived trabecular measures, except the erosion index, showed high correlation (rε [0.91 0.99]). The plate-width measure showed a higher correlation (rε [0.72 0.91]) amongin vivoand micro-CT modalities than its counterpart binary plate-rod characterization-based measure erosion index (rε [0.65 0.81]). Although a strong correlation was observed between micro-structural measures fromin vivoand micro-CT imaging, large shifts in their values forin vivomodalities warrant proper scanner calibration prior to adopting in multi-site and longitudinal studies.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...