A comparative study of trabecular bone micro-structural measurements using different CT modalities
Related Experiment Video
Updated: Dec 4, 2025

Author Spotlight: An Economic and Efficient Method for Quantitative Evaluation of Bone Microarchitecture in a Murine Osteoporosis Model
Published on: September 8, 2023
Indranil Guha1, Benjamin Klintström2, Eva Klintström3
1Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, United States of America.
Abstract:
Osteoporosis, characterized by reduced bone mineral density and micro-architectural degeneration, significantly enhances fracture-risk. There are several viable methods for trabecular bone micro-imaging, which widely vary in terms of technology, reconstruction principle, spatial resolution, and acquisition time. We have performed an excised cadaveric bone specimen study to evaluate different computed tomography (CT)-imaging modalities for trabecular bone micro-structural analysis. Excised cadaveric bone specimens from the distal radius were scanned using micro-CT and fourin vivoCT imaging modalities: high-resolution peripheral quantitative computed tomography (HR-pQCT), dental cone beam CT (CBCT), whole-body multi-row detector CT (MDCT), and extremity CBCT. A new algorithm was developed to optimize soft thresholding parameters for individualin vivoCT modalities for computing quantitative bone volume fraction maps. Finally, agreement of trabecular bone micro-structural measures, derived from differentin vivoCT imaging, with reference measures from micro-CT imaging was examined. Observed values of most trabecular measures, including trabecular bone volume, network area, transverse and plate-rod micro-structure, thickness, and spacing, forin vivoCT modalities were higher than their micro-CT-based reference values. In general, HR-pQCT-based trabecular bone measures were closer to their reference values as compared to otherin vivoCT modalities. Despite large differences in observed values of measures among modalities, high linear correlation (rε [0.94 0.99]) was found between micro-CT andin vivoCT-derived measures of trabecular bone volume, transverse and plate micro-structural volume, and network area. All HR-pQCT-derived trabecular measures, except the erosion index, showed high correlation (rε [0.91 0.99]). The plate-width measure showed a higher correlation (rε [0.72 0.91]) amongin vivoand micro-CT modalities than its counterpart binary plate-rod characterization-based measure erosion index (rε [0.65 0.81]). Although a strong correlation was observed between micro-structural measures fromin vivoand micro-CT imaging, large shifts in their values forin vivomodalities warrant proper scanner calibration prior to adopting in multi-site and longitudinal studies.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...