Watchful waiting of a fetus with zone III amniotic fluid values
R C Goodlin1, J C Anderson, T K Foote
1Department of Obstetrics and Gynecology, University of Colorado Health Sciences Center, Denver.
Journal of Perinatal Medicine
|January 1, 1987
Abstract:
A case of Rh negative, sensitized patient was observed while her amniotic fluid values climbed through zone III of Liley's graph. The fetus was monitored weekly with ultrasound and delivered when it had a mature lung profile. It is not always necessary to proceed with immediate fetal therapy whenever amniotic fluid values are in zone III.