Related Experiment Video
Updated: Dec 4, 2025

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Does Variability Affect the Performance of Front-Face Fluorescence Spectroscopy? A Study Case on Commercial Lebanese
Omar H Dib1,2,3, Jad Rizkalah4, Rita Yaacoub4
1UMR 0914 PNCA, AgroParisTech, INRA, Université Paris-Saclay, 16, rue Claude Bernard, Paris, 75005, France. dib.h.omar@gmail.com.
Abstract:
The potential of front-face fluorescence spectroscopy coupled with chemometric techniques, namely multiple linear regression (MLR) applied on parallel factor (PARAFAC) scores and partial least squares (PLS), was tested on Lebanese olive oil samples possessing natural variability within their chemical parameters. Ninety-six olive oil samples have been harvested at different dates and from two seasons, processed using different extraction methods, collected from different altitudes and other factors that can increase the variability of the samples' chemical composition. Fluorescence excitation-emission matrices (EEM) of the collected samples were measured, and the relationship between them and the chemical parameters was examined. Twenty-two MLR regression models based on PARAFAC scores were generated, the majority of which showed a good correlation coefficient (R > 0.7 for ten predicted variables). A second model using PLS on the unfolded EEM was also conducted to improve the regression and to assess if it can handle the variability in hand. However, similar results, with a slight improvement over the MLR model, were obtained. In a non-experimental design, such variability may hinder the potentials of front-face fluorescence; however average to good MLR and PLS models were obtained, predicting the Lebanese olive oil deterioration quality parameters and fatty acid content.
Related Concept Videos
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectroscopy: Beer–Lambert Law
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Variables Affecting Phosphorescence and Fluorescence
Flame Photometry: Lab
UV–Vis Spectrometers