Related Experiment Video
Updated: Dec 3, 2025

10:28
Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
10.6K
Spectrometric methods of grating constants for different holographic samples
Applied Optics
|October 26, 2020
Summary
Spectrophotometers and angle-resolved spectroscopy efficiently measure holographic grating constants. These spectrometric methods offer accurate alternatives to light optical microscopes for various holographic sample types.
Area of Science:
- Optics and Photonics
- Materials Science
- Spectroscopy
Background:
- Holographic samples are crucial optical components.
- Accurate measurement of grating constants is essential for their application.
- Traditional methods like light optical microscopy can be time-consuming.
Purpose of the Study:
- To develop and validate efficient methods for measuring grating constants of diverse holographic samples.
- To compare the efficacy of spectrophotometry and angle-resolved spectroscopy against traditional microscopy.
Main Methods:
- Utilized spectrophotometers (45/0 configuration) and a macro angle-resolved spectrum system.
- Measured spectral information from six holographic samples across three types (rainbow with light pillars, plain rainbow, matte with light pillars).
- Applied the grating equation to calculate grating constants from spectral data.
Main Results:
- Angle-resolved spectroscopy and 45/0 spectrophotometers are suitable for rainbow holographic samples.
- Angle-resolved spectroscopy is effective for differentiating matte holographic samples.
- Spectrometric method results closely align with those from light optical microscopy.
Conclusions:
- Spectrophotometry and angle-resolved spectroscopy provide efficient and convenient alternatives for measuring holographic grating constants.
- These advanced techniques are applicable to various holographic sample types, including rainbow and matte effects.
- The findings support the adoption of spectrometric methods for routine holographic sample characterization.
Related Concept Videos
IR Spectrometers
2.0K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
2.0K
UV–Vis Spectrometers
2.9K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
2.9K
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
2.4K
A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to...
According to Hooke's law, the vibrational frequency is directly proportional to...
2.4K

