Synchronous respiration: which ventilator rate is best?

A Greenough1, F Greenall, H Gamsu

  • 1Department of Child Health, King's College Hospital, London, United Kingdom.

Acta Paediatrica Scandinavica
|September 1, 1987
PubMed
Summary

For infants requiring mechanical ventilation, a rate of 120 breaths per minute most effectively promotes synchronous breathing. Premature infants with faster spontaneous breathing rates benefit most from this higher ventilator setting.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Non-invasive carbon dioxide monitoring in the UK: a survey of practice within neonatal intensive care.

Anaesthesia·2021
Same author

Review finds insufficient evidence to support the routine use of heated, humidified high-flow nasal cannula use in neonates.

Acta paediatrica (Oslo, Norway : 1992)·2014
Same author

Airways obstruction and pulmonary capillary blood volume in children with sickle cell disease.

Pediatric pulmonology·2013
Same author

Predictors of neonatal morbidity in fetuses with severe isolated congenital diaphragmatic hernia undergoing fetoscopic tracheal occlusion.

Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology·2013
Same author

Antenatal and postnatal management of congenital cystic adenomatoid malformation.

Paediatric respiratory reviews·2012
Same author

Congenital diaphragmatic hernia.

The European respiratory journal·2011

Area of Science:

  • Neonatal Medicine
  • Respiratory Physiology

Background:

  • Mechanical ventilation is crucial for premature infants.
  • Optimizing ventilator settings is essential for respiratory support.
  • Synchronous breathing improves patient outcomes.

Purpose of the Study:

  • To determine the optimal ventilator rate for achieving synchronous respiration in infants.
  • To investigate the correlation between spontaneous respiratory rate, gestational age, and ventilator synchrony.

Main Methods:

  • Twenty-four infants underwent mechanical ventilation at varying rates (30, 60, 120/min).
  • Spontaneous respiratory rate was recorded during brief ventilator disconnections.
  • Synchrony was assessed at different ventilator settings.

Related Experiment Videos

Main Results:

  • A ventilator rate of 120/min achieved synchronous respiration in 17 out of 24 infants.
  • Infants achieving synchrony at 120/min were significantly more premature and had faster spontaneous rates.
  • Six infants required lower ventilator rates (60-75/min) for synchrony.

Conclusions:

  • A ventilator rate of 120/min is most effective for promoting synchronous breathing in a majority of ventilated infants.
  • Infant prematurity and spontaneous respiratory rate are key factors in determining optimal ventilator settings.
  • Individualized ventilator strategies may be necessary for specific infant populations.