Related Experiment Video
Updated: Dec 3, 2025

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
Solvent-free, Noncontact Electrostatic Sampling for Rapid Analysis with Mass Spectrometry: Application to Drugs and
Kenyon M Evans-Nguyen1, Amanda Rivera1, Jannelys Fontanez-Adames1
1The Department of Chemistry, Biochemistry, and Physics, The University of Tampa, Tampa, Florida 33606, United States.
Abstract:
A hand-held Van de Graaf generator is used to apply a high voltage, negligible current electrostatic potential to a wire mesh positioned in close proximity to a particle-laden surface in order to collect those particles for analysis. The electrostatic field effects transfer particles to the mesh without a requirement for mechanical contact between mesh and surface. Analysis of chemicals present in the sampled particles is completed by thermal desorption electrospray ionization. The utility of the method for noncontact sampling is demonstrated using solid drug powder samples, and inorganic explosives dispersed either on solid surfaces or in sand/soil in order to simulate common interfering matrices that might be encountered in the forensic environment. A metal mesh sampling substrate is utilized instead of traditional polymer-based swabs in order to permit thermal desorption at higher temperatures. The method leaves no visible trace of sampling leaving details such as a fingerprint image unperturbed, as demonstrated using fluorescence photography. Direct sampling of trace particles from hard surfaces and skin documents flexibility in the choice of sampling substrates, desorption temperatures, and sampling times. The potential of the device for use in forensic analyses is detailed.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors
Atomic Emission Spectroscopy: Lab
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...