Related Experiment Video
Updated: Dec 3, 2025

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Comparison of flow-independent parameters for grading severity of aortic stenosis using intraoperative
1Department of Cardiac Anesthesia, Aster CMI, Bengaluru, Karnataka, India.
Introduction:
Discrepancies have been reported in grading of severity of aortic stenosis. We propose to compare Aortic valve area by continuity equation, Dimensionless Index and Acceleration time/Ejection time in patients with documented severe aortic stenosis with normal left ventricular function by TEE after induction of anesthesia. This might give use insight about the best parameter we can rely on intra-operatively for decision making.
Methodology:
60 patients with severe AS undergoing elective cardiac surgery were enrolled in our study. Post intubation trans-thoracic echocardiography (TEE) was performed and above mentioned parameters was noted.
Results:
96.7 % of patients continued in severe AS category when AS was measured using AVA as echo parameter. So there is 3.3 % disparity. There was disparity in 13.3% of cases when DI was considered. And there was 43.3% disparity when AT/ET was considered.
Conclusion:
Perioperative grading of aortic stenosis continues to be a challenge for cardiac anesthesiologists. Multiple echocardiographic parameters have to be considered. We have found AVA and DI to have less disparity compared to AT/ET.
More Related Videos
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...