Related Experiment Video
Updated: Dec 3, 2025

Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
Remote operation for non-fluoroscopic navigation of complex tachycardias
Ignacio García-Bolao1,2,3, David Moñino4, Roger Marsal4
1Department of Cardiology and Cardiac Surgery, Arrhythmia Unit, Clinica Universidad de Navarra, Pamplona, Spain. igarciab@unav.es.
Purpose:
Remote system operation technology was developed and applied to a non-fluoroscopic navigation system in order to overcome Spanish mobility restrictions caused by Covid-19 pandemic infection and subsequently used routinely.
Methods And Results:
Fifty consecutive complex ablations were performed in different days using this technology. All these procedures were assisted remotely with the only intervention of a field clinical specialist located at his home who took full control of the navigation system (keyboard, mouse, and screen) and had bidirectional real-time audio/video feedback with the operating physician. Once the connection was established, the remote field clinical specialist replicated the Rhythmia screen at the remote location with all its features, and interacted identically with the physician, essentially with no perceptible differences from being physically present. There were neither interruptions nor perceptible delays in the bidirectional communications between the remote field clinical specialist and the operating physician during the procedures. Video signal delay ranged from 265 to 325 ms. All the procedures were uneventful.
Conclusions:
Remote system operation allowed full teleoperation of a non-fluoroscopic navigation system (keyboard, mouse, and screen) as well as bidirectional real-time audio/video feedback with the operating physician, providing a fully autonomous remote assistance in 50 complex ablation procedures. This technology ensures workflow continuity and optimal workforce flexibility and has relevant and promising implications in the field of training, teaching, and resource optimization that deserves further development.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization I: Pre-Procedure Overview