Related Experiment Video
Updated: Dec 2, 2025

Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment
Published on: September 25, 2009
Coil Occlusion of Right M2 Fusiform Aneurysm After Balloon-Test Occlusion: 2-Dimensional Video
Michael K Tso1, Rimal Hanif Dossani1, Muhammad Waqas1
1Department of Neurosurgery, University at Buffalo School of Medicine and Biomedical Sciences, Buffalo, New York, USA; Department of Neurosurgery, Gates Vascular Institute at Kaleida Health, Buffalo, New York, USA.
Abstract:
We present a 73-year-old man with an incidental right M2 fusiform aneurysm demonstrating growth on serial noninvasive imaging over 5 years (Video 1). After multidisciplinary conference review, the decision was to proceed with intracranial balloon-test occlusion (BTO) followed by coil occlusion if the patient passed this test or by trap and bypass if the patient failed this test. With the patient under moderate conscious sedation, a transfemoral 8F approach was used with positioning of a TracStar 95-cm 088 guide catheter (Imperative Care, Campbell, California, USA) into the distal right cervical ICA. We positioned a Scepter 4-mm × 10-mm compliant dual-lumen balloon microcatheter (MicroVention, Alisa Viejo, California, USA) into the proximal M2. The patient passed the 30-minute BTO including a 15-minute hypotensive challenge with nitroprusside infusion. Our goal was to occlude the aneurysm from distal to proximal for precise thrombosis. A Phenom 17 150-cm microcatheter (Medtronic, Dublin, Ireland) separate from the Scepter balloon microcatheter was positioned in the distal portion of the aneurysm. Coil occlusion was successfully performed with an assortment of complex and helical coils. Sluggish anterograde flow was seen distal to the aneurysm with prominent retrograde filling of the distal right MCA territory via pial collaterals from the right PCA. The patient tolerated the procedure well and was discharged the following day neurologically intact. Six-month follow-up diagnostic angiogram confirmed complete occlusion of the aneurysm. This is the first published video using the elegant approach of intracranial BTO followed by coil occlusion for an intracranial fusiform aneurysm using a dual-lumen balloon microcatheter.
More Related Videos
13:01Intraluminal Middle Cerebral Artery Occlusion MCAO Model for Ischemic Stroke with Laser Doppler Flowmetry Guidance in Mice
Published on: May 8, 2011
07:17Author Spotlight: A Novel Standardized Technique for Real-Time Biomedical Imaging of Acute Myocardial Injury
Published on: March 22, 2024
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm III: Interprofessional Care