Related Experiment Video
Updated: Dec 2, 2025

Pretreatment of Lignocellulosic Biomass with Low-cost Ionic Liquids
Published on: August 10, 2016
Factors Affecting the Nonsolvent-Induced Phase Separation of Cellulose from Ionic Liquid-Based Solutions
Alexandra S M Wittmar1,2, Dereck Koch1, Oleg Prymak3,2
1Lehrstuhl für Technische Chemie II, Universität Duisburg-Essen, 45141 Essen, Germany.
Abstract:
In the present work, we report for the first time an in-depth study of the factors influencing porous cellulose film structure formation during the nonsolvent-induced phase separation (NIPS) process from biopolymer solutions in ionic liquid-based solvents. The length of the alkyl chain of the ionic liquid's cation, the solvent/co-solvent ratio, and the type of the cellulose precursor used were found to have great influence both on cellulose solution formation and properties and to the NIPS process with water acting as nonsolvent. In the undiluted form, both studied ionic liquids proved to dissolve almost equally well the cellulose; however, due to differences in viscosities of the formed biopolymer solutions and due to differences in miscibility with water of the two ionic liquids, the used ionic liquid had a strong influence on the film's porous structure formation. The use of increasing amounts of an aprotic co-solvent, here dimethylsulfoxide, improved biopolymer solubilization and also led to the formation of a more pronounced macroporous structure during the NIPS process. The cellulose type also affected the porous structure generation during the NIPS process: with the increase of the molecular weight of the precursor, the viscosity of the formed biopolymer solution increased and the tendency to generate macroporous structures decreased.
Related Concept Videos
Factors Affecting Solubility
Recrystallization: Solid–Solution Equilibria
Solubility
A solution is a homogeneous mixture composed of a solvent, the major component, and a solute, the minor component. The physical state of a solution—solid, liquid, or gas—is typically the same as that of the solvent. Solute concentrations are often described with qualitative terms such as dilute (of relatively low concentration) and concentrated (of relatively high concentration).
In a solution, the solute particles (molecules,...
Solution Formation
This selective...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...

