Related Experiment Video
Updated: Dec 2, 2025

Treatment of Platelet Products with Riboflavin and UV Light: Effectiveness Against High Titer Bacterial Contamination
Published on: August 24, 2015
Extension of platelet shelf life with an improved bacterial testing algorithm.
Sandra Ramirez-Arcos1,2, Stephanie Evans1, Terri McIntyre1
1Canadian Blood Services, Ottawa, Ontario, Canada.
Extending platelet concentrate shelf life to 7 days using bacterial screening reduced product outdating and transfusion-related septic events. This enhanced safety while improving blood supply efficiency.
Area of Science:
- Transfusion Medicine
- Microbiology
- Blood Banking
Background:
- Platelet concentrate (PC) shelf life was extended to 7 days at Canadian Blood Services.
- A large-volume, delayed-sampling bacterial screening algorithm was implemented to ensure safety.
Purpose of the Study:
- To present the development study and postimplementation results of an extended PC shelf life bacterial screening algorithm.
- To evaluate the impact of the new screening method on bacterial detection, product outdating, and transfusion safety.
Main Methods:
- Development study involved inoculating PCs with various bacteria and incubating for 7 days with daily sampling.
- Postimplementation analysis included screening 223,156 PC pools and 39,725 apheresis units from August 2017 to December 2019.
- BacT/ALERT cultures and bacterial quantification were used for screening.
Main Results:
- The algorithm detected bacteria like Klebsiella pneumoniae, Serratia marcescens, and Staphylococcus aureus at low concentrations within 24 hours.
- Staphylococcus epidermidis required over 48 hours for detection at low concentrations.
- Postimplementation, confirmed-positive results were 0.09% for pools and 0.04% for apheresis units, predominantly Cutibacterium acnes.
- Combined PC outdating decreased from 18.9% to 13.1%.
- One nonfatal septic reaction occurred with a 7-day PC contaminated with S. epidermidis.
- Septic transfusion events decreased approximately threefold.
Conclusions:
- Screening 7-day PCs enhanced bacterial detection, particularly anaerobes, and reduced product outdating.
- The incidence of septic transfusion events significantly decreased.
- Further surveillance is needed to fully assess the value of anaerobic cultures and residual safety risks.