Related Experiment Video
Updated: Jul 24, 2026

Bio-layer Interferometry for Measuring Kinetics of Protein-protein Interactions and Allosteric Ligand Effects
Published on: February 18, 2014
A multisensor approach for improved protein A load phase monitoring by conductivity-based background subtraction of
Laura Rolinger1, Matthias Rüdt1, Jürgen Hubbuch1
1Karlsruhe Institute of Technology, Karlsruhe, Germany.
Abstract:
Real-time monitoring and control of protein A capture steps by process analytical technologies (PATs) promises significant economic benefits due to the improved usage of the column's binding capacity, by eliminating time-consuming off-line analytics and costly resin lifetime studies, and enabling continuous production. The PAT method proposed in this study relies on ultraviolet (UV) spectroscopy with a dynamic background subtraction based on the leveling out of the conductivity signal. This point in time can be used to collect a reference spectrum for removing the majority of spectral contributions by process-related contaminants. The removal of the background spectrum facilitates chemometric model building and model accuracy. To demonstrate the benefits of this method, five different feedstocks from our industry partner were used to mix the load material for a case study. To our knowledge, such a large design space, which covers possible variations in upstream condition besides the product concentration, has not been disclosed yet. By applying the conductivity-based background subtraction, the root mean square error of prediction (RMSEP) of the partial least squares (PLS) model improved from 0.2080 to 0.0131 g . Finally, the potential of the background subtraction method was further evaluated for single wavelength-based predictions to facilitate implementation in production processes. An RMSEP of 0.0890 g with univariate linear regression was achieved, showing that by subtraction of the background better prediction accuracy is achieved then without subtraction and a PLS model. In summary, the developed background subtraction method is versatile, enables accurate prediction results, and is easily implemented into existing chromatography setups with typically already integrated sensors.
More Related Videos
08:46Electronic Tongue Generating Continuous Recognition Patterns for Protein Analysis
Published on: September 16, 2014
08:22Calibration-free In Vitro Quantification of Protein Homo-oligomerization Using Commercial Instrumentation and Free, Open Source Brightness Analysis Software
Published on: July 17, 2018