The Application of 1% Methylene Blue Dye As a Single Technique in Breast Cancer Sentinel Node Biopsy
Published on: June 1, 2019
Meta-analysis Comparing Fluorescence Imaging with Radioisotope and Blue Dye-Guided Sentinel Node Identification for
Martha S Kedrzycki1,2,3, Maria Leiloglou4,5, Hutan Ashrafian5
1Hamlyn Centre, Institute of Global Health Innovation, Imperial College London, London, UK. martha.kedrzycki@imperial.ac.uk.
Introduction:
Conventional methods for axillary sentinel lymph node biopsy (SLNB) are fraught with complications such as allergic reactions, skin tattooing, radiation, and limitations on infrastructure. A novel technique has been developed for lymphatic mapping utilizing fluorescence imaging. This meta-analysis aims to compare the gold standard blue dye and radioisotope (BD-RI) technique with fluorescence-guided SLNB using indocyanine green (ICG).
Methods:
This study was registered with PROSPERO (CRD42019129224). The MEDLINE, EMBASE, Scopus, and Web of Science databases were searched using the Medical Subject Heading (MESH) terms 'Surgery' AND 'Lymph node' AND 'Near infrared fluorescence' AND 'Indocyanine green'. Studies containing raw data on the sentinel node identification rate in breast cancer surgery were included. A heterogeneity test (using Cochran's Q) determined the use of fixed- or random-effects models for pooled odds ratios (OR).
Results:
Overall, 1748 studies were screened, of which 10 met the inclusion criteria for meta-analysis. ICG was equivalent to radioisotope (RI) at sentinel node identification (OR 2.58, 95% confidence interval [CI] 0.35-19.08, p < 0.05) but superior to blue dye (BD) (OR 9.07, 95% CI 6.73-12.23, p < 0.05). Furthermore, ICG was superior to the gold standard BD-RI technique (OR 4.22, 95% CI 2.17-8.20, p < 0.001).
Conclusion:
Fluorescence imaging for axillary sentinel node identification with ICG is equivalent to the single technique using RI, and superior to the dual technique (RI-BD) and single technique with BD. Hospitals using RI and/or BD could consider changing their practice to ICG given the comparable efficacy and improved safety profile, as well as the lesser burden on hospital infrastructure.